Channel 1 Tx event configuration register
| TX_LIM | This register is used to configure the maximum entries that CHANNEL%s can send out. |
| TX_LOOP_NUM | This register is used to configure the maximum loop count when tx_conti_mode is valid. |
| TX_LOOP_CNT_EN | This register is the enabled bit for loop count. |
| LOOP_COUNT_RESET | This register is used to reset the loop count when tx_conti_mode is valid. |
| LOOP_STOP_EN | This bit is used to enable the loop send stop function after the loop counter counts to loop number for CHANNEL%s. |